Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Journal of Forensic Medicine ; (6): 182-185, 2011.
Article in Chinese | WPRIM | ID: wpr-983647

ABSTRACT

OBJECTIVE@#To study the value of slow vertex response (SVR) in the evaluation of hearing loss by comparing the hearing thresholds acquired with SVR and pure tone audiometry (PTA).@*METHODS@#Twenty-five subjects (40 ears) with sensorineural hearing loss were tested by PTA and SVR. According to the thresholds of PTA, these ears were subdivided into mild, moderate and severe hearing loss groups, and rank sum test was performed on the thresholds of SVR and PTA for all the hearing loss groups. Then, the correlation between PTA thresholds and SVR thresholds was analyzed and the mathematical models were established for predicting behavioral thresholds by the thresholds of SVR.@*RESULTS@#At four test frequencies (0.5, 1, 2 and 4kHz), the thresholds of SVR had high correlations with thresholds of PTA. Four liner regression equations were established, and the correlation coefficient(r) were 0.971, 0.976, 0.957 and 0.928, respectively (P < 0.05). Back substitution test showed that the liner regression equations would be an easy method for estimating the behavior thresholds.@*CONCLUSION@#The behavioral threshold can be well judged and evaluated by the liner regression equations established with SVR thresholds.


Subject(s)
Female , Humans , Male , Acoustic Stimulation/methods , Audiometry, Evoked Response , Audiometry, Pure-Tone , Auditory Cortex/physiology , Auditory Threshold/physiology , Evoked Potentials, Auditory/physiology , Forensic Medicine/methods , Hearing Loss/physiopathology , Predictive Value of Tests , Regression Analysis , Severity of Illness Index
2.
Chinese Medical Journal ; (24): 1811-1814, 2008.
Article in English | WPRIM | ID: wpr-265943

ABSTRACT

<p><b>BACKGROUND</b>Recently, bilateral transpedicular kyphoplasty with a single balloon was performed for osteoporotic vertebral body compression fractures (OVCFs) to reduce the fees of the operation, but the time of operation and radiation exposure are longer. The aim of this study was to determine the safety and effectiveness of a single balloon cross-midline expansion via unipedicular approach in kyphoplasty for OVCFs.</p><p><b>METHODS</b>Thirty-six patients with painful OVCFs (61 vertebrae) were enrolled in this research. Unilateral transpedicular puncture was performed under the fluoroscopy monitoring of an oblique angle down the pedicle. A single balloon was introduced through unipedicular approach. The final balloon position was in the midline of the vertebral body with the balloon cross-midline expansion and bone cement filled. Clinical outcomes were determined by comparison of the preoperative and postoperative visual analogue scale (VAS) and Oswestry disability index (ODI). Radiographic assessment included restoration of vertebral height and correction of kyphosis. Follow-up was conducted for 6 - 12 months (mean 9.2 months).</p><p><b>RESULTS</b>Thirty-six consecutive patients with 61 vertebrae were successfully operated on with a mean operation time of 37.4 minutes per vertebra. All patients had dramatic pain relief and functional recovery within 96 hours after the procedure with no surgery or device-related complications. VAS score improved from 7.27 +/- 1.02 preoperatively to 2.71 +/- 0.75 postoperatively (P < 0.01). ODI score was decreased from (71.14 +/- 10.94)% preoperatively to (26.56 +/- 6.35)% postoperatively. The average loss of anterior body height was (14.33 +/- 2.76) mm before procedure and (10.03 +/- 1.83) mm after procedure (P < 0.01), while the average loss of middle body height was (10.15 +/- 2.70) mm before procedure and (5.89 +/- 1.83) mm after procedure (P < 0.01). The kyphotic deformity was corrected from (23.43 +/- 5.00) degree to (16.16 +/- 2.77) degree (P < 0.01). The pain relief and functional recovery were substantial and maintained to the last follow-up without any re-collapse or adjacent level fracture.</p><p><b>CONCLUSIONS</b>A single-balloon cross-midline expansion via unipedicular approach in kyphoplasty for OVCFs is an effective and safe procedure with less cost, less operation time and less radiation exposure when compared with the conventional kyphoplasty technique.</p>


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Fractures, Compression , General Surgery , Osteoporosis , Spinal Fractures , General Surgery , Treatment Outcome , Vertebroplasty , Methods
3.
Chinese Journal of Radiology ; (12)2000.
Article in Chinese | WPRIM | ID: wpr-680177

ABSTRACT

Objective To discuss the technique and technique-related issues of percutaneous kyphoplasty(PKP).Methods The study involved 69 vertebrae in 51 cases of painful osteoporotic vertebral compressive fractures.Under X-ray fluoroscopy monitoring,the fractured vertebral bodies were treated by kyphonplasty with inflatable balloon.The preoperative and postoperative vertebral height and Cobb angle in radiography were measured and analyzed.Results All patients tolerated the procedure well with dramatic pain relief within 72 hours after the procedure.No clinical complication was found.The loss heights of the anterior and mid portion of the vertebral body reduced from 15?4mm and 11?4mm preoperatively to 10? 4mm and 6?3mm postoperatively,respectively.Cobb angle corrected averagely from 22??6? preoperatively to 12??4?.There was significant difference between preoperative and postoperative measures (P

SELECTION OF CITATIONS
SEARCH DETAIL